Rob's Gas Toolkit
UK residential — quick-access calcs + reference. Choose a tool.
Calculators
Site calcs covering UP/1B, UP/1A, G3 and BS 5440. All work offline.
Forms & records
Generate signed PDFs for handover. Every printed form is auto-saved to Saved Records.
Fuel
Meter
Result
Volumes per IGEM/UP/1B Ed 4. Stabilisation and tightness periods auto-band by IV.
Installation volume
Imported from Purge calc — re-import after edits.
Test setup
Procedure timers
Each stage beeps + vibrates when the time is up.
① Let-by test (1 min)
Pressure must hold steady — any rise indicates let-by.
② Stabilisation (1 min)
Allow temperature/pressure to settle before reading.
③ Tightness test (3 min — Note initial reading at start)
Note the pressure at start, then again when the alarm sounds — the difference is the measured drop entered above.
Result
UP/1B Ed 4 short test: 1-min stabilisation + 2-min test. MPPD shown is for typical small-bore domestic; larger/commercial installations require full UP/1 procedure with calculated MPPD.
Fuel
Mode
Meter
① Initial reading
Run the appliance ≥ 10 min. All other gas appliances OFF. Note the last 3 digits before the timer.
② Timer
TB 162: 60 s acceptable for metric. Use 120 s for older procedure.
③ Final reading
Tip: enter at the moment the timer alarm sounds. The diff is gas used during the timed window.
Result
Compare to the appliance data badge (gross input). Allow ≥10 min running for accuracy.
Material
Fuel
Inputs
UP/1A: each elbow / tee adds ~0.5 m equivalent length.
Result
1 mbar total drop budget. Tabulated capacities are informative; verify with full UP/1A method on critical jobs.
Record
Registered business details
Landlord / agent (if applicable)
Inspection / installation address
Faults & rectification
CO & smoke alarms
Other comments / observations
Issued & received
Output
Create PDF: builds the record, saves it to Saved Records, and opens your phone's Save-as-PDF dialog. After that you can email the customer (attach the saved PDF) or print.
Record
Form for completion in accordance with the manufacturer's instructions, Water Supplies (Water Fittings) Regulations, Building Regulations Approved Doc G3, and the requirements of BS EN 806 / BS EN 12897.
Registered business details
Landlord / agent (if applicable)
Inspection / installation address
Hot water storage vessel — details
Operating details
Discharge pipework D1 (relief valve to tundish)
Discharge pipework D2 (tundish to point of termination)
Tip: Use the D2 Discharge calculator on the home screen to size D2 length / bends against G3 worked equivalents before signing off.
Installation & commissioning
Observations & recommendations
Company representative
Output
Create PDF: builds the record, saves it to Saved Records, and opens your phone's Save-as-PDF dialog. Then email or print.
Record
Boiler installation commissioning record. Required by manufacturers for warranty registration. Cross-reference with the appliance Benchmark logbook.
Registered business
Customer / property
Landlord / agent (if applicable)
Boiler details
Water treatment
Pressures & temperatures
Combustion analysis
Record the analyser readings at high fire (full rate). Initial = first read; Final = post-adjustment.
Initial reading
Final reading
Customer hand-over
Sign-off
Output
Create PDF: builds the commissioning record, saves it to Saved Records, and opens Save-as-PDF. The customer needs this for their warranty.
Warning Notice
Issue this notice when an appliance has been classified At Risk, Immediately Dangerous, or Not to Current Standards. Hand a copy to the user; retain a copy on file.
Status
AR — capable of being made safe. ID — must not be used. NCS — installed before current regs but not unsafe.
Registered business
Customer / property
Landlord / agent (if applicable)
Appliance
Fault & risk
Action taken
Receipt
Output
Create PDF: builds the notice, saves it to Saved Records, and opens Save-as-PDF. Then email or print. Hand a copy to the user before leaving site.
Saved Records
Every printed CP12, unvented commissioning, benchmark, or warning notice is saved here. Tap a record to re-open it; tap "Re-print" to regenerate the PDF.
Relief valve outlet (D1)
D2 run
Building Regs Approved Doc G3 worked-equivalent. Tundish-onwards only — not the 500 mm vertical drop or first metre.
Result
Reference diagrams
Letter labels match the clearance values below — tap any letter to jump to it.
House corner — horizontal flue
Carport / balcony
Two terminals across a passage
Pitched roof — vertical flue
Diagrams are schematic — not to scale. BS 5440 Pt 1, fanned-flue gas appliances ≤ 70 kW net. Always confirm with appliance MI.
Search clearances
Appliance type
Heat input
Result
Search
Matches across fault codes AND boiler models. Tap a model to open its full service hub (tech data, gas valve, fault codes, parts, wiring).
Filter
Pick a brand + model to get a button on every fault that opens the manual PDF jumped to the relevant section.
Boilers — browse by model
Pick a brand and model to open its service hub (Service Info, Service Mode, Gas Valve / Fan, Fault Codes, Wiring…) or jump straight to the manufacturer's manual.
Tap a model name to open its service hub. Tap 📄 PDF to open the manual directly.
My details
Saved on this device only. Used by the CP12 "Use my details" button.
Backup & restore
Export every saved record + your profile as a JSON file. Useful before you change phone, or as a periodic backup.